Eurgle ESC-80A MANUALS 10page/14pages
· Changing the recording parameters
Recommend: In order to well and accurately record the flight data, please know and program the recording
configurations first before use, otherwise may cause losing of some data.
- Click the menu ‘Data Logger’.
- ‘Recorder Configuration’ (Shortcuts button ) .
- Click ‘Connect’ button to display current configuration.
- Sampling Rate (1,2,3,5,10,20,30 ) times/a second.*
*The default sampling rate of ESC-80A is 3 times in a second. The possible recording time is
decided by the storage and set sampling rate. The longest recording time is 68 minutes.
Possible Recording Time means longest time the recorder can record with the set sampling rate.
Minimum Flying Time: with the set sampling rate, the minimum flying time of ESC should be more than the
listed in above form, otherwise the software can not read out and display the data on the PC window.
- Record type. ‘Not reverse’ and
‘reverse’.*
*‘Not reverse’ indicates the data
log- ger cannot record any more when
the space is filled up; ‘reverse’ indicates the data logger can record indefinitely by overlapping the for-
mer data and do a cycle. ‘Not reverse’ is default.
Sampling Rate Possible Recording Time Minimum Flying Time
Once/ a second Approx. 68.1 minutes
> 60 seconds
Twice/ a second Approx. 34.05 minutes
> 30 seconds
3 times/ a second Approx. 22.7 minutes
> 20 seconds
5 times/a second Approx. 13.62 minutes
> 10 seconds
10 times/a second Approx. 6.81 minutes
> 5 seconds
15 times/a second Approx. 3.405 minutes
> 3 seconds
30 times/a second Approx. 2.27 minutes
> 2 seconds